GET https://content.gamingdesktop.com.au/admin/description/32012/edit?page=767

Forms

  • Description
    • ea_form_fieldset_01KSPNQ0BT652KCGR0YFG48TRF
    • sku
    • lsDescription
    • alloyDescription
    • alloyShortDescription
    • alloyFeaturesBenefits
    • mmtDescription
    • dsDescription
    • dsFeaturesHtml
    • icecatDescription
    • icecatShortDescription
    • icecatFeatures
    • icecatSpecifications
    • icecatMiddleDescription
    • icecatLongSummary
    • ea_form_fieldset_close_01KSPNQ0BT652KCGR0YFG48TRF
    • _token

Description

Form type:
"EasyCorp\Bundle\EasyAdminBundle\Form\Type\CrudFormType"

Errors

This form has no errors.

Default Data

Property Value
Model Format same as normalized format
Normalized Format
App\Entity\Description {#846
  -id: 32012
  -sku: "OR1500ERM1U"
  -lsDescription: null
  -alloyDescription: null
  -alloyShortDescription: null
  -alloyFeaturesBenefits: null
  -mmtDescription: null
  -dsDescription: "CP Smart App Rack 1500VA UPS"
  -dsFeaturesHtml: """
    <h2>Specifications:</h2>\n
    <ul>\n
    <li>Phase: Single Phase</li>\n
    <li>Form Factor: Rackmount</li>\n
    <li>UPS Topology: Line-interactive</li>\n
    <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
    <li>Nominal Input Voltage ( Vac ): 230</li>\n
    <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
    <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
    <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
    <li>Input Frequency Detection: Auto-sensing</li>\n
    <li>Input Connector Type: IEC C14</li>\n
    <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
    <li>Power Cord Length: 1.83m</li>\n
    <li>Capacity (VA): 1500</li>\n
    <li>Capacity (Watts): 900</li>\n
    <li>On Battery Waveform: Simulated Sine Wave</li>\n
    <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
    <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
    <li>Power Factor: 0.6</li>\n
    <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
    <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
    <li>Outlet(s) - Total: 6</li>\n
    <li>Outlet Type: IEC C13 x 6</li>\n
    <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
    <li>Outlet(s) - Surge-Only Protected: 2</li>\n
    <li>Typical Transfer Time ( ms ): 4</li>\n
    <li>Runtime at Half Load ( min ): 11</li>\n
    <li>Runtime at Full Load ( min ): 2.5</li>\n
    <li>Typical Recharge Time ( Hours ): 8</li>\n
    <li>Start On Battery: Yes</li>\n
    <li>User-replaceable: Yes</li>\n
    <li>Hot-swappable: Yes</li>\n
    <li>Replacement Battery Pack (RBP): RBP0026</li>\n
    <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
    <li>Surge Suppression ( Joules ): 810</li>\n
    <li>EMI/RFI Filtration: Yes</li>\n
    <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
    <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
    <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
    <li>HID Compliant USB Port(s): 1</li>\n
    <li>Serial Port: Dry Contact</li>\n
    <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
    <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
    <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
    <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
    <li>Enclosure Construction: Metal</li>\n
    <li>Rackmount Ears: Yes</li>\n
    <li>Dimensions: 433 x 44 x 389mm</li>\n
    <li>Weight: 14.9kg</li>\n
    <li>Installed Rack Height ( U ): 1</li>\n
    <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
    <li>Certifications: CE | EAC | RCM | RoHS</li>\n
    <li>Warranty: 2 Years</li>\n
    </ul>\n
    \n
    <h2>Features:</h2>\n
    <ul>\n
    <li>Line-interactive UPS Topology</li>\n
    <li>Simulated Sine Wave Output</li>\n
    <li>Overload Protection</li>\n
    <li>Surge and Spike Protection</li>\n
    <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
    <li>USB Connectivity Port</li>\n
    <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
    <li>Energy Saving Technology</li>\n
    <li>Automatic Voltage Regulation (AVR)</li>\n
    <li>Hot-swappable Batteries</li>\n
    <li>EMI and RFI Filtration</li>\n
    <li>LCD Status Display</li>\n
    <li>PowerPanel Management Software</li>\n
    </ul>\n
    \n
    <h2>What's in the box?</h2>\n
    <ul>\n
    <li>1 x OR1500ERM1U UPS</li>\n
    <li>1 x Rackmount Ears</li>\n
    <li>1 x Power Cord</li>\n
    <li>1 x USB Cable</li>\n
    <li>1 x User Manual</li>\n
    </ul>
    """
  -icecatDescription: null
  -icecatShortDescription: null
  -icecatFeatures: null
  -icecatSpecifications: null
  -icecatMiddleDescription: null
  -icecatLongSummary: null
  -icecatBulletPoints: null
}
View Format same as normalized format

Submitted Data

This form was not submitted.

Passed Options

Option Passed Value Resolved Value
attr
[
  "class" => "ea-edit-form"
  "id" => "edit-Description-form"
]
[
  "class" => "ea-edit-form"
  "id" => "edit-Description-form"
]
data
App\Entity\Description {#846
  -id: 32012
  -sku: "OR1500ERM1U"
  -lsDescription: null
  -alloyDescription: null
  -alloyShortDescription: null
  -alloyFeaturesBenefits: null
  -mmtDescription: null
  -dsDescription: "CP Smart App Rack 1500VA UPS"
  -dsFeaturesHtml: """
    <h2>Specifications:</h2>\n
    <ul>\n
    <li>Phase: Single Phase</li>\n
    <li>Form Factor: Rackmount</li>\n
    <li>UPS Topology: Line-interactive</li>\n
    <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
    <li>Nominal Input Voltage ( Vac ): 230</li>\n
    <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
    <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
    <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
    <li>Input Frequency Detection: Auto-sensing</li>\n
    <li>Input Connector Type: IEC C14</li>\n
    <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
    <li>Power Cord Length: 1.83m</li>\n
    <li>Capacity (VA): 1500</li>\n
    <li>Capacity (Watts): 900</li>\n
    <li>On Battery Waveform: Simulated Sine Wave</li>\n
    <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
    <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
    <li>Power Factor: 0.6</li>\n
    <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
    <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
    <li>Outlet(s) - Total: 6</li>\n
    <li>Outlet Type: IEC C13 x 6</li>\n
    <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
    <li>Outlet(s) - Surge-Only Protected: 2</li>\n
    <li>Typical Transfer Time ( ms ): 4</li>\n
    <li>Runtime at Half Load ( min ): 11</li>\n
    <li>Runtime at Full Load ( min ): 2.5</li>\n
    <li>Typical Recharge Time ( Hours ): 8</li>\n
    <li>Start On Battery: Yes</li>\n
    <li>User-replaceable: Yes</li>\n
    <li>Hot-swappable: Yes</li>\n
    <li>Replacement Battery Pack (RBP): RBP0026</li>\n
    <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
    <li>Surge Suppression ( Joules ): 810</li>\n
    <li>EMI/RFI Filtration: Yes</li>\n
    <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
    <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
    <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
    <li>HID Compliant USB Port(s): 1</li>\n
    <li>Serial Port: Dry Contact</li>\n
    <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
    <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
    <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
    <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
    <li>Enclosure Construction: Metal</li>\n
    <li>Rackmount Ears: Yes</li>\n
    <li>Dimensions: 433 x 44 x 389mm</li>\n
    <li>Weight: 14.9kg</li>\n
    <li>Installed Rack Height ( U ): 1</li>\n
    <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
    <li>Certifications: CE | EAC | RCM | RoHS</li>\n
    <li>Warranty: 2 Years</li>\n
    </ul>\n
    \n
    <h2>Features:</h2>\n
    <ul>\n
    <li>Line-interactive UPS Topology</li>\n
    <li>Simulated Sine Wave Output</li>\n
    <li>Overload Protection</li>\n
    <li>Surge and Spike Protection</li>\n
    <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
    <li>USB Connectivity Port</li>\n
    <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
    <li>Energy Saving Technology</li>\n
    <li>Automatic Voltage Regulation (AVR)</li>\n
    <li>Hot-swappable Batteries</li>\n
    <li>EMI and RFI Filtration</li>\n
    <li>LCD Status Display</li>\n
    <li>PowerPanel Management Software</li>\n
    </ul>\n
    \n
    <h2>What's in the box?</h2>\n
    <ul>\n
    <li>1 x OR1500ERM1U UPS</li>\n
    <li>1 x Rackmount Ears</li>\n
    <li>1 x Power Cord</li>\n
    <li>1 x USB Cable</li>\n
    <li>1 x User Manual</li>\n
    </ul>
    """
  -icecatDescription: null
  -icecatShortDescription: null
  -icecatFeatures: null
  -icecatSpecifications: null
  -icecatMiddleDescription: null
  -icecatLongSummary: null
  -icecatBulletPoints: null
}
same as passed value
entityDto
EasyCorp\Bundle\EasyAdminBundle\Dto\EntityDto {#769
  -isAccessible: true
  -instance: App\Entity\Description {#846
    -id: 32012
    -sku: "OR1500ERM1U"
    -lsDescription: null
    -alloyDescription: null
    -alloyShortDescription: null
    -alloyFeaturesBenefits: null
    -mmtDescription: null
    -dsDescription: "CP Smart App Rack 1500VA UPS"
    -dsFeaturesHtml: """
      <h2>Specifications:</h2>\n
      <ul>\n
      <li>Phase: Single Phase</li>\n
      <li>Form Factor: Rackmount</li>\n
      <li>UPS Topology: Line-interactive</li>\n
      <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
      <li>Nominal Input Voltage ( Vac ): 230</li>\n
      <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
      <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
      <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
      <li>Input Frequency Detection: Auto-sensing</li>\n
      <li>Input Connector Type: IEC C14</li>\n
      <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
      <li>Power Cord Length: 1.83m</li>\n
      <li>Capacity (VA): 1500</li>\n
      <li>Capacity (Watts): 900</li>\n
      <li>On Battery Waveform: Simulated Sine Wave</li>\n
      <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
      <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
      <li>Power Factor: 0.6</li>\n
      <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
      <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
      <li>Outlet(s) - Total: 6</li>\n
      <li>Outlet Type: IEC C13 x 6</li>\n
      <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
      <li>Outlet(s) - Surge-Only Protected: 2</li>\n
      <li>Typical Transfer Time ( ms ): 4</li>\n
      <li>Runtime at Half Load ( min ): 11</li>\n
      <li>Runtime at Full Load ( min ): 2.5</li>\n
      <li>Typical Recharge Time ( Hours ): 8</li>\n
      <li>Start On Battery: Yes</li>\n
      <li>User-replaceable: Yes</li>\n
      <li>Hot-swappable: Yes</li>\n
      <li>Replacement Battery Pack (RBP): RBP0026</li>\n
      <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
      <li>Surge Suppression ( Joules ): 810</li>\n
      <li>EMI/RFI Filtration: Yes</li>\n
      <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
      <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
      <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
      <li>HID Compliant USB Port(s): 1</li>\n
      <li>Serial Port: Dry Contact</li>\n
      <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
      <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
      <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
      <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
      <li>Enclosure Construction: Metal</li>\n
      <li>Rackmount Ears: Yes</li>\n
      <li>Dimensions: 433 x 44 x 389mm</li>\n
      <li>Weight: 14.9kg</li>\n
      <li>Installed Rack Height ( U ): 1</li>\n
      <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
      <li>Certifications: CE | EAC | RCM | RoHS</li>\n
      <li>Warranty: 2 Years</li>\n
      </ul>\n
      \n
      <h2>Features:</h2>\n
      <ul>\n
      <li>Line-interactive UPS Topology</li>\n
      <li>Simulated Sine Wave Output</li>\n
      <li>Overload Protection</li>\n
      <li>Surge and Spike Protection</li>\n
      <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
      <li>USB Connectivity Port</li>\n
      <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
      <li>Energy Saving Technology</li>\n
      <li>Automatic Voltage Regulation (AVR)</li>\n
      <li>Hot-swappable Batteries</li>\n
      <li>EMI and RFI Filtration</li>\n
      <li>LCD Status Display</li>\n
      <li>PowerPanel Management Software</li>\n
      </ul>\n
      \n
      <h2>What's in the box?</h2>\n
      <ul>\n
      <li>1 x OR1500ERM1U UPS</li>\n
      <li>1 x Rackmount Ears</li>\n
      <li>1 x Power Cord</li>\n
      <li>1 x USB Cable</li>\n
      <li>1 x User Manual</li>\n
      </ul>
      """
    -icecatDescription: null
    -icecatShortDescription: null
    -icecatFeatures: null
    -icecatSpecifications: null
    -icecatMiddleDescription: null
    -icecatLongSummary: null
    -icecatBulletPoints: null
  }
  -primaryKeyValue: 32012
  -fields: EasyCorp\Bundle\EasyAdminBundle\Collection\FieldCollection {#226 …}
  -actions: EasyCorp\Bundle\EasyAdminBundle\Collection\ActionCollection {#1616 …}
  -defaultActionUrl: null
  -fqcn: "App\Entity\Description"
  -metadata: Doctrine\ORM\Mapping\ClassMetadata {#799 …}
  -permission: null
}
same as passed value
translation_domain
"messages"
same as passed value

Resolved Options

Option Value
action
""
allow_extra_fields
true
allow_file_upload
false
attr
[
  "class" => "ea-edit-form"
  "id" => "edit-Description-form"
]
attr_translation_parameters
[]
auto_initialize
true
block_name
null
block_prefix
null
by_reference
true
compound
true
constraints
[]
csrf_field_name
"_token"
csrf_message
"The CSRF token is invalid. Please try to resubmit the form."
csrf_protection
true
csrf_token_id
"submit"
csrf_token_manager
Symfony\Component\Security\Csrf\SameOriginCsrfTokenManager {#613
  -requestStack: Symfony\Component\HttpFoundation\RequestStack {#336 …}
  -logger: Monolog\Logger {#157 …}
  -fallbackCsrfTokenManager: Symfony\Component\Security\Csrf\CsrfTokenManager {#402 …}
  -tokenIds: [
    "submit" => 0
    "authenticate" => 1
    "logout" => 2
  ]
  -checkHeader: 1
  -cookieName: "csrf-token"
}
data
App\Entity\Description {#846
  -id: 32012
  -sku: "OR1500ERM1U"
  -lsDescription: null
  -alloyDescription: null
  -alloyShortDescription: null
  -alloyFeaturesBenefits: null
  -mmtDescription: null
  -dsDescription: "CP Smart App Rack 1500VA UPS"
  -dsFeaturesHtml: """
    <h2>Specifications:</h2>\n
    <ul>\n
    <li>Phase: Single Phase</li>\n
    <li>Form Factor: Rackmount</li>\n
    <li>UPS Topology: Line-interactive</li>\n
    <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
    <li>Nominal Input Voltage ( Vac ): 230</li>\n
    <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
    <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
    <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
    <li>Input Frequency Detection: Auto-sensing</li>\n
    <li>Input Connector Type: IEC C14</li>\n
    <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
    <li>Power Cord Length: 1.83m</li>\n
    <li>Capacity (VA): 1500</li>\n
    <li>Capacity (Watts): 900</li>\n
    <li>On Battery Waveform: Simulated Sine Wave</li>\n
    <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
    <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
    <li>Power Factor: 0.6</li>\n
    <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
    <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
    <li>Outlet(s) - Total: 6</li>\n
    <li>Outlet Type: IEC C13 x 6</li>\n
    <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
    <li>Outlet(s) - Surge-Only Protected: 2</li>\n
    <li>Typical Transfer Time ( ms ): 4</li>\n
    <li>Runtime at Half Load ( min ): 11</li>\n
    <li>Runtime at Full Load ( min ): 2.5</li>\n
    <li>Typical Recharge Time ( Hours ): 8</li>\n
    <li>Start On Battery: Yes</li>\n
    <li>User-replaceable: Yes</li>\n
    <li>Hot-swappable: Yes</li>\n
    <li>Replacement Battery Pack (RBP): RBP0026</li>\n
    <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
    <li>Surge Suppression ( Joules ): 810</li>\n
    <li>EMI/RFI Filtration: Yes</li>\n
    <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
    <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
    <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
    <li>HID Compliant USB Port(s): 1</li>\n
    <li>Serial Port: Dry Contact</li>\n
    <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
    <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
    <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
    <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
    <li>Enclosure Construction: Metal</li>\n
    <li>Rackmount Ears: Yes</li>\n
    <li>Dimensions: 433 x 44 x 389mm</li>\n
    <li>Weight: 14.9kg</li>\n
    <li>Installed Rack Height ( U ): 1</li>\n
    <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
    <li>Certifications: CE | EAC | RCM | RoHS</li>\n
    <li>Warranty: 2 Years</li>\n
    </ul>\n
    \n
    <h2>Features:</h2>\n
    <ul>\n
    <li>Line-interactive UPS Topology</li>\n
    <li>Simulated Sine Wave Output</li>\n
    <li>Overload Protection</li>\n
    <li>Surge and Spike Protection</li>\n
    <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
    <li>USB Connectivity Port</li>\n
    <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
    <li>Energy Saving Technology</li>\n
    <li>Automatic Voltage Regulation (AVR)</li>\n
    <li>Hot-swappable Batteries</li>\n
    <li>EMI and RFI Filtration</li>\n
    <li>LCD Status Display</li>\n
    <li>PowerPanel Management Software</li>\n
    </ul>\n
    \n
    <h2>What's in the box?</h2>\n
    <ul>\n
    <li>1 x OR1500ERM1U UPS</li>\n
    <li>1 x Rackmount Ears</li>\n
    <li>1 x Power Cord</li>\n
    <li>1 x USB Cable</li>\n
    <li>1 x User Manual</li>\n
    </ul>
    """
  -icecatDescription: null
  -icecatShortDescription: null
  -icecatFeatures: null
  -icecatSpecifications: null
  -icecatMiddleDescription: null
  -icecatLongSummary: null
  -icecatBulletPoints: null
}
data_class
"App\Entity\Description"
disabled
false
empty_data
Closure(FormInterface $form) {#1625
  class: "Symfony\Component\Form\Extension\Core\Type\FormType"
  use: {
    $class: "App\Entity\Description"
  }
}
entityDto
EasyCorp\Bundle\EasyAdminBundle\Dto\EntityDto {#769
  -isAccessible: true
  -instance: App\Entity\Description {#846
    -id: 32012
    -sku: "OR1500ERM1U"
    -lsDescription: null
    -alloyDescription: null
    -alloyShortDescription: null
    -alloyFeaturesBenefits: null
    -mmtDescription: null
    -dsDescription: "CP Smart App Rack 1500VA UPS"
    -dsFeaturesHtml: """
      <h2>Specifications:</h2>\n
      <ul>\n
      <li>Phase: Single Phase</li>\n
      <li>Form Factor: Rackmount</li>\n
      <li>UPS Topology: Line-interactive</li>\n
      <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
      <li>Nominal Input Voltage ( Vac ): 230</li>\n
      <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
      <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
      <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
      <li>Input Frequency Detection: Auto-sensing</li>\n
      <li>Input Connector Type: IEC C14</li>\n
      <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
      <li>Power Cord Length: 1.83m</li>\n
      <li>Capacity (VA): 1500</li>\n
      <li>Capacity (Watts): 900</li>\n
      <li>On Battery Waveform: Simulated Sine Wave</li>\n
      <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
      <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
      <li>Power Factor: 0.6</li>\n
      <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
      <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
      <li>Outlet(s) - Total: 6</li>\n
      <li>Outlet Type: IEC C13 x 6</li>\n
      <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
      <li>Outlet(s) - Surge-Only Protected: 2</li>\n
      <li>Typical Transfer Time ( ms ): 4</li>\n
      <li>Runtime at Half Load ( min ): 11</li>\n
      <li>Runtime at Full Load ( min ): 2.5</li>\n
      <li>Typical Recharge Time ( Hours ): 8</li>\n
      <li>Start On Battery: Yes</li>\n
      <li>User-replaceable: Yes</li>\n
      <li>Hot-swappable: Yes</li>\n
      <li>Replacement Battery Pack (RBP): RBP0026</li>\n
      <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
      <li>Surge Suppression ( Joules ): 810</li>\n
      <li>EMI/RFI Filtration: Yes</li>\n
      <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
      <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
      <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
      <li>HID Compliant USB Port(s): 1</li>\n
      <li>Serial Port: Dry Contact</li>\n
      <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
      <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
      <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
      <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
      <li>Enclosure Construction: Metal</li>\n
      <li>Rackmount Ears: Yes</li>\n
      <li>Dimensions: 433 x 44 x 389mm</li>\n
      <li>Weight: 14.9kg</li>\n
      <li>Installed Rack Height ( U ): 1</li>\n
      <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
      <li>Certifications: CE | EAC | RCM | RoHS</li>\n
      <li>Warranty: 2 Years</li>\n
      </ul>\n
      \n
      <h2>Features:</h2>\n
      <ul>\n
      <li>Line-interactive UPS Topology</li>\n
      <li>Simulated Sine Wave Output</li>\n
      <li>Overload Protection</li>\n
      <li>Surge and Spike Protection</li>\n
      <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
      <li>USB Connectivity Port</li>\n
      <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
      <li>Energy Saving Technology</li>\n
      <li>Automatic Voltage Regulation (AVR)</li>\n
      <li>Hot-swappable Batteries</li>\n
      <li>EMI and RFI Filtration</li>\n
      <li>LCD Status Display</li>\n
      <li>PowerPanel Management Software</li>\n
      </ul>\n
      \n
      <h2>What's in the box?</h2>\n
      <ul>\n
      <li>1 x OR1500ERM1U UPS</li>\n
      <li>1 x Rackmount Ears</li>\n
      <li>1 x Power Cord</li>\n
      <li>1 x USB Cable</li>\n
      <li>1 x User Manual</li>\n
      </ul>
      """
    -icecatDescription: null
    -icecatShortDescription: null
    -icecatFeatures: null
    -icecatSpecifications: null
    -icecatMiddleDescription: null
    -icecatLongSummary: null
    -icecatBulletPoints: null
  }
  -primaryKeyValue: 32012
  -fields: EasyCorp\Bundle\EasyAdminBundle\Collection\FieldCollection {#226 …}
  -actions: EasyCorp\Bundle\EasyAdminBundle\Collection\ActionCollection {#1616 …}
  -defaultActionUrl: null
  -fqcn: "App\Entity\Description"
  -metadata: Doctrine\ORM\Mapping\ClassMetadata {#799 …}
  -permission: null
}
error_bubbling
true
error_mapping
[]
extra_fields_message
"This form should not contain extra fields."
form_attr
false
getter
null
help
null
help_attr
[]
help_html
false
help_translation_parameters
[]
inherit_data
false
invalid_message
"This value is not valid."
invalid_message_parameters
[]
is_empty_callback
null
label
null
label_attr
[]
label_format
null
label_html
false
label_translation_parameters
[]
mapped
true
method
"POST"
post_max_size_message
"The uploaded file was too large. Please try to upload a smaller file."
priority
0
property_path
null
required
true
row_attr
[]
setter
null
translation_domain
"messages"
trim
true
upload_max_size_message
Closure() {#1623
  class: "Symfony\Component\Form\Extension\Validator\Type\UploadValidatorExtension"
  use: {
    $translator: Symfony\Component\Translation\DataCollectorTranslator {#967 …}
    $message: Closure() {#1626 …}
    $translationDomain: "validators"
  }
}
validation_groups
null

View Vars

Variable Value
action
""
attr
[
  "class" => "ea-edit-form"
  "id" => "edit-Description-form"
]
attr_translation_parameters
[]
block_prefixes
[
  "form"
  "ea_crud"
  "_Description"
]
cache_key
"_Description_ea_crud"
compound
true
data
App\Entity\Description {#846
  -id: 32012
  -sku: "OR1500ERM1U"
  -lsDescription: null
  -alloyDescription: null
  -alloyShortDescription: null
  -alloyFeaturesBenefits: null
  -mmtDescription: null
  -dsDescription: "CP Smart App Rack 1500VA UPS"
  -dsFeaturesHtml: """
    <h2>Specifications:</h2>\n
    <ul>\n
    <li>Phase: Single Phase</li>\n
    <li>Form Factor: Rackmount</li>\n
    <li>UPS Topology: Line-interactive</li>\n
    <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
    <li>Nominal Input Voltage ( Vac ): 230</li>\n
    <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
    <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
    <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
    <li>Input Frequency Detection: Auto-sensing</li>\n
    <li>Input Connector Type: IEC C14</li>\n
    <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
    <li>Power Cord Length: 1.83m</li>\n
    <li>Capacity (VA): 1500</li>\n
    <li>Capacity (Watts): 900</li>\n
    <li>On Battery Waveform: Simulated Sine Wave</li>\n
    <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
    <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
    <li>Power Factor: 0.6</li>\n
    <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
    <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
    <li>Outlet(s) - Total: 6</li>\n
    <li>Outlet Type: IEC C13 x 6</li>\n
    <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
    <li>Outlet(s) - Surge-Only Protected: 2</li>\n
    <li>Typical Transfer Time ( ms ): 4</li>\n
    <li>Runtime at Half Load ( min ): 11</li>\n
    <li>Runtime at Full Load ( min ): 2.5</li>\n
    <li>Typical Recharge Time ( Hours ): 8</li>\n
    <li>Start On Battery: Yes</li>\n
    <li>User-replaceable: Yes</li>\n
    <li>Hot-swappable: Yes</li>\n
    <li>Replacement Battery Pack (RBP): RBP0026</li>\n
    <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
    <li>Surge Suppression ( Joules ): 810</li>\n
    <li>EMI/RFI Filtration: Yes</li>\n
    <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
    <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
    <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
    <li>HID Compliant USB Port(s): 1</li>\n
    <li>Serial Port: Dry Contact</li>\n
    <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
    <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
    <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
    <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
    <li>Enclosure Construction: Metal</li>\n
    <li>Rackmount Ears: Yes</li>\n
    <li>Dimensions: 433 x 44 x 389mm</li>\n
    <li>Weight: 14.9kg</li>\n
    <li>Installed Rack Height ( U ): 1</li>\n
    <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
    <li>Certifications: CE | EAC | RCM | RoHS</li>\n
    <li>Warranty: 2 Years</li>\n
    </ul>\n
    \n
    <h2>Features:</h2>\n
    <ul>\n
    <li>Line-interactive UPS Topology</li>\n
    <li>Simulated Sine Wave Output</li>\n
    <li>Overload Protection</li>\n
    <li>Surge and Spike Protection</li>\n
    <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
    <li>USB Connectivity Port</li>\n
    <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
    <li>Energy Saving Technology</li>\n
    <li>Automatic Voltage Regulation (AVR)</li>\n
    <li>Hot-swappable Batteries</li>\n
    <li>EMI and RFI Filtration</li>\n
    <li>LCD Status Display</li>\n
    <li>PowerPanel Management Software</li>\n
    </ul>\n
    \n
    <h2>What's in the box?</h2>\n
    <ul>\n
    <li>1 x OR1500ERM1U UPS</li>\n
    <li>1 x Rackmount Ears</li>\n
    <li>1 x Power Cord</li>\n
    <li>1 x USB Cable</li>\n
    <li>1 x User Manual</li>\n
    </ul>
    """
  -icecatDescription: null
  -icecatShortDescription: null
  -icecatFeatures: null
  -icecatSpecifications: null
  -icecatMiddleDescription: null
  -icecatLongSummary: null
  -icecatBulletPoints: null
}
disabled
false
ea_crud_form
[
  "assets" => "** This variable no longer stores field assets. Instead, use "ea.crud.fieldAssets()" in your Twig template."
  "entity" => EasyCorp\Bundle\EasyAdminBundle\Dto\EntityDto {#769
    -isAccessible: true
    -instance: App\Entity\Description {#846
      -id: 32012
      -sku: "OR1500ERM1U"
      -lsDescription: null
      -alloyDescription: null
      -alloyShortDescription: null
      -alloyFeaturesBenefits: null
      -mmtDescription: null
      -dsDescription: "CP Smart App Rack 1500VA UPS"
      -dsFeaturesHtml: """
        <h2>Specifications:</h2>\n
        <ul>\n
        <li>Phase: Single Phase</li>\n
        <li>Form Factor: Rackmount</li>\n
        <li>UPS Topology: Line-interactive</li>\n
        <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
        <li>Nominal Input Voltage ( Vac ): 230</li>\n
        <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
        <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
        <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
        <li>Input Frequency Detection: Auto-sensing</li>\n
        <li>Input Connector Type: IEC C14</li>\n
        <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
        <li>Power Cord Length: 1.83m</li>\n
        <li>Capacity (VA): 1500</li>\n
        <li>Capacity (Watts): 900</li>\n
        <li>On Battery Waveform: Simulated Sine Wave</li>\n
        <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
        <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
        <li>Power Factor: 0.6</li>\n
        <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
        <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
        <li>Outlet(s) - Total: 6</li>\n
        <li>Outlet Type: IEC C13 x 6</li>\n
        <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
        <li>Outlet(s) - Surge-Only Protected: 2</li>\n
        <li>Typical Transfer Time ( ms ): 4</li>\n
        <li>Runtime at Half Load ( min ): 11</li>\n
        <li>Runtime at Full Load ( min ): 2.5</li>\n
        <li>Typical Recharge Time ( Hours ): 8</li>\n
        <li>Start On Battery: Yes</li>\n
        <li>User-replaceable: Yes</li>\n
        <li>Hot-swappable: Yes</li>\n
        <li>Replacement Battery Pack (RBP): RBP0026</li>\n
        <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
        <li>Surge Suppression ( Joules ): 810</li>\n
        <li>EMI/RFI Filtration: Yes</li>\n
        <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
        <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
        <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
        <li>HID Compliant USB Port(s): 1</li>\n
        <li>Serial Port: Dry Contact</li>\n
        <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
        <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
        <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
        <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
        <li>Enclosure Construction: Metal</li>\n
        <li>Rackmount Ears: Yes</li>\n
        <li>Dimensions: 433 x 44 x 389mm</li>\n
        <li>Weight: 14.9kg</li>\n
        <li>Installed Rack Height ( U ): 1</li>\n
        <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
        <li>Certifications: CE | EAC | RCM | RoHS</li>\n
        <li>Warranty: 2 Years</li>\n
        </ul>\n
        \n
        <h2>Features:</h2>\n
        <ul>\n
        <li>Line-interactive UPS Topology</li>\n
        <li>Simulated Sine Wave Output</li>\n
        <li>Overload Protection</li>\n
        <li>Surge and Spike Protection</li>\n
        <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
        <li>USB Connectivity Port</li>\n
        <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
        <li>Energy Saving Technology</li>\n
        <li>Automatic Voltage Regulation (AVR)</li>\n
        <li>Hot-swappable Batteries</li>\n
        <li>EMI and RFI Filtration</li>\n
        <li>LCD Status Display</li>\n
        <li>PowerPanel Management Software</li>\n
        </ul>\n
        \n
        <h2>What's in the box?</h2>\n
        <ul>\n
        <li>1 x OR1500ERM1U UPS</li>\n
        <li>1 x Rackmount Ears</li>\n
        <li>1 x Power Cord</li>\n
        <li>1 x USB Cable</li>\n
        <li>1 x User Manual</li>\n
        </ul>
        """
      -icecatDescription: null
      -icecatShortDescription: null
      -icecatFeatures: null
      -icecatSpecifications: null
      -icecatMiddleDescription: null
      -icecatLongSummary: null
      -icecatBulletPoints: null
    }
    -primaryKeyValue: 32012
    -fields: EasyCorp\Bundle\EasyAdminBundle\Collection\FieldCollection {#226 …}
    -actions: EasyCorp\Bundle\EasyAdminBundle\Collection\ActionCollection {#1616 …}
    -defaultActionUrl: null
    -fqcn: "App\Entity\Description"
    -metadata: Doctrine\ORM\Mapping\ClassMetadata {#799 …}
    -permission: null
  }
  "form_tabs" => []
  "form_fieldsets" => []
]
ea_vars
EasyCorp\Bundle\EasyAdminBundle\Dto\FormVarsDto {#1952
  -fieldDto: null
  -entityDto: null
}
errors
Symfony\Component\Form\FormErrorIterator {#1853
  -errors: []
  -form: Symfony\Component\Form\Form {#1794 …}
}
form
Symfony\Component\Form\FormView {#1702 …5}
full_name
"Description"
help
null
help_attr
[]
help_html
false
help_translation_parameters
[]
id
"Description"
label
null
label_attr
[]
label_format
null
label_html
false
label_translation_parameters
[]
method
"POST"
multipart
false
name
"Description"
priority
0
required
true
row_attr
[]
submitted
false
translation_domain
"messages"
unique_block_prefix
"_Description"
valid
true
value
App\Entity\Description {#846
  -id: 32012
  -sku: "OR1500ERM1U"
  -lsDescription: null
  -alloyDescription: null
  -alloyShortDescription: null
  -alloyFeaturesBenefits: null
  -mmtDescription: null
  -dsDescription: "CP Smart App Rack 1500VA UPS"
  -dsFeaturesHtml: """
    <h2>Specifications:</h2>\n
    <ul>\n
    <li>Phase: Single Phase</li>\n
    <li>Form Factor: Rackmount</li>\n
    <li>UPS Topology: Line-interactive</li>\n
    <li>Energy Saving Technology: GreenPower UPS Bypass Technology</li>\n
    <li>Nominal Input Voltage ( Vac ): 230</li>\n
    <li>Input Voltage Range ( Vac ): 165 - 271</li>\n
    <li>Adjustable Voltage Range ( Vac ): 253 - 271 Vac | 189 - 207 Vac</li>\n
    <li>Input Frequency ( Hz ): 50  3 | 60  3</li>\n
    <li>Input Frequency Detection: Auto-sensing</li>\n
    <li>Input Connector Type: IEC C14</li>\n
    <li>Detachable Power Cord Plug Type: IEC C14 x 1</li>\n
    <li>Power Cord Length: 1.83m</li>\n
    <li>Capacity (VA): 1500</li>\n
    <li>Capacity (Watts): 900</li>\n
    <li>On Battery Waveform: Simulated Sine Wave</li>\n
    <li>On Battery Voltage(s) ( Vac ): 230  10 %</li>\n
    <li>On Battery Frequency ( Hz ): 50  1% | 60  1%</li>\n
    <li>Power Factor: 0.6</li>\n
    <li>Automatic Voltage Regulation (AVR): Single Boost</li>\n
    <li>Overload Protection: Internal Current Limiting | Circuit Breaker</li>\n
    <li>Outlet(s) - Total: 6</li>\n
    <li>Outlet Type: IEC C13 x 6</li>\n
    <li>Outlet(s) - Battery & Surge Protected: 4</li>\n
    <li>Outlet(s) - Surge-Only Protected: 2</li>\n
    <li>Typical Transfer Time ( ms ): 4</li>\n
    <li>Runtime at Half Load ( min ): 11</li>\n
    <li>Runtime at Full Load ( min ): 2.5</li>\n
    <li>Typical Recharge Time ( Hours ): 8</li>\n
    <li>Start On Battery: Yes</li>\n
    <li>User-replaceable: Yes</li>\n
    <li>Hot-swappable: Yes</li>\n
    <li>Replacement Battery Pack (RBP): RBP0026</li>\n
    <li>Replacement Battery Pack (RBP) Quantity ( pcs ): 1</li>\n
    <li>Surge Suppression ( Joules ): 810</li>\n
    <li>EMI/RFI Filtration: Yes</li>\n
    <li>Phone/Network Protection RJ11/RJ45 (Combo): 1-in | 1-out</li>\n
    <li>LCD Information Display: Operation Type | Power Status | Battery Status | Load Status | Other Information</li>\n
    <li>LCD Setting & Control: Mode Setting | Alarm Setting | Input & Output</li>\n
    <li>HID Compliant USB Port(s): 1</li>\n
    <li>Serial Port: Dry Contact</li>\n
    <li>Audible Alarms: Battery Mode | Low Battery | Overload | UPS Fault</li>\n
    <li>Management Cable ( pcs ): Power Cord x4 | USB Cable x1</li>\n
    <li>Power Management Software: PowerPanel Business (Recommended)</li>\n
    <li>SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205</li>\n
    <li>Enclosure Construction: Metal</li>\n
    <li>Rackmount Ears: Yes</li>\n
    <li>Dimensions: 433 x 44 x 389mm</li>\n
    <li>Weight: 14.9kg</li>\n
    <li>Installed Rack Height ( U ): 1</li>\n
    <li>Online Thermal Dissipation ( BTU/hr ): 24</li>\n
    <li>Certifications: CE | EAC | RCM | RoHS</li>\n
    <li>Warranty: 2 Years</li>\n
    </ul>\n
    \n
    <h2>Features:</h2>\n
    <ul>\n
    <li>Line-interactive UPS Topology</li>\n
    <li>Simulated Sine Wave Output</li>\n
    <li>Overload Protection</li>\n
    <li>Surge and Spike Protection</li>\n
    <li>Phone/Fax/Modem/DSL/Network Protection</li>\n
    <li>USB Connectivity Port</li>\n
    <li>SNMP/HTTP Remote Management Capability (Optional)</li>\n
    <li>Energy Saving Technology</li>\n
    <li>Automatic Voltage Regulation (AVR)</li>\n
    <li>Hot-swappable Batteries</li>\n
    <li>EMI and RFI Filtration</li>\n
    <li>LCD Status Display</li>\n
    <li>PowerPanel Management Software</li>\n
    </ul>\n
    \n
    <h2>What's in the box?</h2>\n
    <ul>\n
    <li>1 x OR1500ERM1U UPS</li>\n
    <li>1 x Rackmount Ears</li>\n
    <li>1 x Power Cord</li>\n
    <li>1 x USB Cable</li>\n
    <li>1 x User Manual</li>\n
    </ul>
    """
  -icecatDescription: null
  -icecatShortDescription: null
  -icecatFeatures: null
  -icecatSpecifications: null
  -icecatMiddleDescription: null
  -icecatLongSummary: null
  -icecatBulletPoints: null
}